This extreme measurement example is from a DesignCon 2020 paper, titled “A Method for Dynamic Load Current Testing with a Benchtop Power Supply” [1]. My good friend and colleague, Heidi Barnes, from Keysight, performed the bulk of this seemingly impossible effort. The goal was to determine the dynamic current of the FPGA by measuring the AC current in an external voltage regulator module (VRM) using a transformation of the PCB S-parameters and the simultaneous measurement of the AC voltages across the PDN.
While there are a few different challenges presented here, the first is that on the PCB there is not an accessible point to measure the VRM current. Rather, an external DC-DC converter module was soldered to the PCB using wide copper foil to minimize the inductance of the connection. Since most current probes are inductive, they would impact the measurement. So, a PEM Rogowski current probe was used, despite the noisy nature of this type of probe. This external DC-DC converter and Rogowski probe setup is shown in Figure 1.
Figure 1 The external VTM DC-DC converter module is seen, soldered to the PCB using wide copper foil and the Rogowski probe is soldered around the positive foil power lead.
Samples of the decoupling capacitors were measured and modeled and loaded into Keysight Pathwave ADS. The S-parameters were extracted using the ADS PIPRO simulator, and a model of the setup was constructed, including a measurement of the inductance of the VRM at the PCB point of contact.
Click here to read the entire article.
Comments